Form of presentation | Articles in international journals and collections |
Year of publication | 2015 |
Язык | русский |
|
Budnikov German Konstantinovich, author
Evtyugin Gennadiy Arturovich, author
Stoykov Ivan Ivanovich, author
Stoykova Ekaterina Evgenevna, author
|
|
Sorvin Mikhail Igorevich, postgraduate kfu
Shurpik Dmitriy Nikolaevich, postgraduate kfu
|
Bibliographic description in the original language |
Stoikova, E.E. Solid-contact potentiometric sensor based on polyaniline and unsubstituted pillar[5]arene [Text] / E.E. Stoikova, M.I. Sorvin, D.N. Shurpik, H.C. Budnikov, I.I. Stoikov, G.A. Evtugyn // Electroanalysis. - 2015. - V.27. - P.440-449. |
Annotation |
A novel potentiometric sensor based on screen-printed carbon electrode covered with electropolymerized polyaniline and unsubstituted pillar[5]arene as ionophore has been developed and tested in potentiometric measurements of pH and metal ions. The introduction of pillar[5]arene improved the reversibility of the pH response in the range from 2.0 to 9.0 with the slope of 45 mV/pH. Among metal cations, the response to Fe(3+) and Ag(+)ions was referred to PANI redox conversion whereas the signal toward Cu(2+) in the range from 1.0x10-6 to 1.0x10-2 M (limit of detection 3.0x10-7 M) to specific interaction with the macrocycle. |
Keywords |
Potentiometric sensor, Solid-contact sensor, Pillar[5]arene, Polyaniline, Electropolymerization |
The name of the journal |
ELECTROANAL
|
URL |
http://onlinelibrary.wiley.com/doi/10.1002/elan.201400494/abstract |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=99358&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Budnikov German Konstantinovich |
ru_RU |
dc.contributor.author |
Evtyugin Gennadiy Arturovich |
ru_RU |
dc.contributor.author |
Stoykov Ivan Ivanovich |
ru_RU |
dc.contributor.author |
Stoykova Ekaterina Evgenevna |
ru_RU |
dc.contributor.author |
Sorvin Mikhail Igorevich |
ru_RU |
dc.contributor.author |
Shurpik Dmitriy Nikolaevich |
ru_RU |
dc.date.accessioned |
2015-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2015-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2015 |
ru_RU |
dc.identifier.citation |
Stoikova, E.E. Solid-contact potentiometric sensor based on polyaniline and unsubstituted pillar[5]arene [Text] / E.E. Stoikova, M.I. Sorvin, D.N. Shurpik, H.C. Budnikov, I.I. Stoikov, G.A. Evtugyn // Electroanalysis. - 2015. - V.27. - P.440-449. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=99358&p_lang=2 |
ru_RU |
dc.description.abstract |
ELECTROANAL |
ru_RU |
dc.description.abstract |
A novel potentiometric sensor based on screen-printed carbon electrode covered with electropolymerized polyaniline and unsubstituted pillar[5]arene as ionophore has been developed and tested in potentiometric measurements of pH and metal ions. The introduction of pillar[5]arene improved the reversibility of the pH response in the range from 2.0 to 9.0 with the slope of 45 mV/pH. Among metal cations, the response to Fe(3+) and Ag(+)ions was referred to PANI redox conversion whereas the signal toward Cu(2+) in the range from 1.0x10-6 to 1.0x10-2 M (limit of detection 3.0x10-7 M) to specific interaction with the macrocycle. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Potentiometric sensor |
ru_RU |
dc.subject |
Solid-contact sensor |
ru_RU |
dc.subject |
Pillar[5]arene |
ru_RU |
dc.subject |
Polyaniline |
ru_RU |
dc.subject |
Electropolymerization |
ru_RU |
dc.title |
Solid-contact potentiometric sensor based on polyaniline and unsubstituted pillar[5]arene |
ru_RU |
dc.type |
Articles in international journals and collections |
ru_RU |
|