Form of presentation | Articles in international journals and collections |
Year of publication | 2019 |
Язык | английский |
|
Budnikov German Konstantinovich, author
Guss Ekaterina Valerevna, author
Davletshin Rustam Rifkhatovich, author
Ziyatdinova Guzel Kamilevna, author
|
|
Guss Ekaterina Valerevna, postgraduate kfu
|
Bibliographic description in the original language |
Ziyatdinova, G. Selective determination of total capsaicinoids in plant material using poly(gallic acid)-modified electrode / G. Ziyatdinova, E. Kozlova, H. Budnikov, R. Davletshin // Electroanalysis. – 2019. – V. 31. – № 2. – P. 222-230. |
Annotation |
Novel voltammetric approach for the selective determination of total capsaicinoids has been developed using glassy carbon electrode modified with multi-walled carbon nanotubes and poly(gallic acid) (PGA/MWNT/GCE). The modified electrode provides significant improvements in the capsaicinoids voltammetric characteristics in comparison to GCE and MWNT/GCE. The electrooxidation of capsaicinoids is irreversible adsorption-controlled process with the anodic transfer coefficient of 0.49-0.53 and heterogeneous electron transfer rate constant of 1300-2400s(-1). The analytical ranges of 0.010-1.0 and 1.0-50M for capsaicin, 0.025-0.75 and 0.75-75M for dihydrocapsaicin and 0.025-5.0 and 5.0-75M for nonivamide with the detection limits of 2.9, 5.9 and 6.1nM, respectively, have been obtained using differential pulse voltammetry (DPV). The selectivity of the capsaicinoids quantification in the presence of ascorbic acid, -tocopherol and carotenoids is shown. The method has been tested on the samples of red hot pepper spices and Capsicum annuum L. tinctures. The results correspond to the chromatographic data. |
Keywords |
Voltammetry, Capsaicinoids, Electropolymerization, Modified electrodes, Plant analysis |
The name of the journal |
ELECTROANALYSIS
|
URL |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85053057135&doi=10.1002%2felan.201800455&partnerID=40&md5=82b3ca571fac113fd2f19e01fa8b887d |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=197933&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Budnikov German Konstantinovich |
ru_RU |
dc.contributor.author |
Guss Ekaterina Valerevna |
ru_RU |
dc.contributor.author |
Davletshin Rustam Rifkhatovich |
ru_RU |
dc.contributor.author |
Ziyatdinova Guzel Kamilevna |
ru_RU |
dc.contributor.author |
Guss Ekaterina Valerevna |
ru_RU |
dc.date.accessioned |
2019-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2019-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2019 |
ru_RU |
dc.identifier.citation |
Ziyatdinova, G. Selective determination of total capsaicinoids in plant material using poly(gallic acid)-modified electrode / G. Ziyatdinova, E. Kozlova, H. Budnikov, R. Davletshin // Electroanalysis. – 2019. – V. 31. – № 2. – P. 222-230. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=197933&p_lang=2 |
ru_RU |
dc.description.abstract |
ELECTROANALYSIS |
ru_RU |
dc.description.abstract |
Novel voltammetric approach for the selective determination of total capsaicinoids has been developed using glassy carbon electrode modified with multi-walled carbon nanotubes and poly(gallic acid) (PGA/MWNT/GCE). The modified electrode provides significant improvements in the capsaicinoids voltammetric characteristics in comparison to GCE and MWNT/GCE. The electrooxidation of capsaicinoids is irreversible adsorption-controlled process with the anodic transfer coefficient of 0.49-0.53 and heterogeneous electron transfer rate constant of 1300-2400s(-1). The analytical ranges of 0.010-1.0 and 1.0-50M for capsaicin, 0.025-0.75 and 0.75-75M for dihydrocapsaicin and 0.025-5.0 and 5.0-75M for nonivamide with the detection limits of 2.9, 5.9 and 6.1nM, respectively, have been obtained using differential pulse voltammetry (DPV). The selectivity of the capsaicinoids quantification in the presence of ascorbic acid, -tocopherol and carotenoids is shown. The method has been tested on the samples of red hot pepper spices and Capsicum annuum L. tinctures. The results correspond to the chromatographic data. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Voltammetry |
ru_RU |
dc.subject |
Capsaicinoids |
ru_RU |
dc.subject |
Electropolymerization |
ru_RU |
dc.subject |
Modified electrodes |
ru_RU |
dc.subject |
Plant analysis |
ru_RU |
dc.title |
Selective Determination of Total Capsaicinoids in Plant Material Using Poly(Gallic Acid)-modified Electrode |
ru_RU |
dc.type |
Articles in international journals and collections |
ru_RU |
|