Form of presentation | Articles in international journals and collections |
Year of publication | 2017 |
Язык | английский |
|
Khodov Ilya Anatolevich, author
|
Bibliographic description in the original language |
Khodov I.A., Accuracy of determination of self-diffusion coefficients in studies of porphyrin-based complexes by 2D DOSY//Macroheterocycles. - 2017. - Vol.10, Is.3. - P.313-316. |
Annotation |
Influence of chemical exchange processes on the accuracy of determination of self-diffusion complexes of porphyrinnickel complexes was shown. A method of estimating the inaccuracy of the self-diffusion coefficients for an inverted porphyrin complex was proposed. The values obtained using two different approaches to recording DOSY spectra, STE and CPMG, were compared. Allowing for exchange was shown to be important for accurate diffusion measurements and correct interpretation of results obtained in studied of molecular-level processes. ? ISUCT Publishing. |
Keywords |
2D DOSY, Chemical exchange, J-modulation, N-confused porphyrins, NMR, Self-diffusion coefficients. |
The name of the journal |
Macroheterocycles
|
URL |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038111591&doi=10.6060%2fmhc170200k&partnerID=40&md5=ad24d5aff28c841be00eae481b75267f |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=184175&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Khodov Ilya Anatolevich |
ru_RU |
dc.date.accessioned |
2017-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2017-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2017 |
ru_RU |
dc.identifier.citation |
Khodov I.A., Accuracy of determination of self-diffusion coefficients in studies of porphyrin-based complexes by 2D DOSY//Macroheterocycles. - 2017. - Vol.10, Is.3. - P.313-316. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=184175&p_lang=2 |
ru_RU |
dc.description.abstract |
Macroheterocycles |
ru_RU |
dc.description.abstract |
Influence of chemical exchange processes on the accuracy of determination of self-diffusion complexes of porphyrinnickel complexes was shown. A method of estimating the inaccuracy of the self-diffusion coefficients for an inverted porphyrin complex was proposed. The values obtained using two different approaches to recording DOSY spectra, STE and CPMG, were compared. Allowing for exchange was shown to be important for accurate diffusion measurements and correct interpretation of results obtained in studied of molecular-level processes. ? ISUCT Publishing. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
2D DOSY |
ru_RU |
dc.subject |
Chemical exchange |
ru_RU |
dc.subject |
J-modulation |
ru_RU |
dc.subject |
N-confused porphyrins |
ru_RU |
dc.subject |
NMR |
ru_RU |
dc.subject |
Self-diffusion coefficients. |
ru_RU |
dc.title |
Accuracy of determination of self-diffusion coefficients in studies of porphyrin-based complexes by 2D DOSY |
ru_RU |
dc.type |
Articles in international journals and collections |
ru_RU |
|